Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
2.
Herz ; 49(1): 33-42, 2024 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-38092975

RESUMO

In August 2023 the new European guidelines on the management of infective endocarditis were published by the European Society of Cardiology (ESC). Numerous recommendations were revised and supplemented by new ones. This review article outlines the essential modifications of the current ESC guidelines focusing on the prevention including antibiotic prophylaxis, the role of the endocarditis team, the revision of the diagnostic criteria, the paradigm shift towards oral antibiotic treatment, the timing and the indications for surgical treatment as well as the relevance of infections of cardiovascular implantable electronic devices.


Assuntos
Cardiologia , Endocardite Bacteriana , Endocardite , Humanos , Endocardite/terapia , Endocardite/tratamento farmacológico , Endocardite Bacteriana/terapia , Endocardite Bacteriana/prevenção & controle , Antibacterianos/uso terapêutico , Antibioticoprofilaxia
3.
J Am Heart Assoc ; 11(24): e7965, 2022 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-36533610

RESUMO

Background In the absence of randomized controlled trials, reports from nonrandomized studies comparing valve-in-valve implantation (ViV) to redo surgical aortic valve replacement (rAVR) have shown inconsistent results. Methods and Results PubMed/MEDLINE, Google Scholar, and CENTRAL (Cochrane Central Register of Controlled Trials) were searched through December 2021. Meta-Analysis of Observational Studies in Epidemiology guidelines were followed. The protocol was registered at the International Prospective Register of Systematic Reviews. Random effects models were applied. The primary outcomes of interest were short-term and midterm mortality. Secondary outcomes included stroke, myocardial infarction, acute renal failure, and permanent pacemaker implantation, as well as prosthetic aortic valve regurgitation, mean transvalvular gradient, and severe prosthesis-patient mismatch. Of 8881 patients included in 15 studies, 4458 (50.2%) underwent ViV and 4423 (49.8%) rAVR. Short-term mortality was 2.8% in patients undergoing ViV compared with 5.0% in patients undergoing rAVR (risk ratio [RR] 0.55 [95% CI, 0.34-0.91], P=0.02). Midterm mortality did not differ in patients undergoing ViV compared with patients undergoing rAVR (hazard ratio, 1.27 [95% CI, 0.72-2.25]). The rate of acute kidney failure was lower following ViV, (RR, 0.54 [95% CI, 0.33-0.88], P=0.02), whereas prosthetic aortic valve regurgitation (RR, 4.18 [95% CI, 1.88-9.3], P=0.003) as well as severe patient-prothesis mismatch (RR, 3.12 [95% CI, 2.35-4.1], P<0.001) occurred more frequently. The mean transvalvular gradient was higher following ViV (standard mean difference, 0.44 [95% CI, 0.15-0.72], P=0.008). There were no significant differences between groups with respect to stroke (P=0.26), myocardial infarction (P=0.93), or pacemaker implantation (P=0.21). Conclusions Results of this meta-analysis demonstrate better short-term mortality after ViV compared with rAVR. Midterm mortality was similar between groups. Given the likely selection bias in these individual reports, an adequately powered multicenter randomized clinical trial with sufficiently long follow-up in patients with low-to-intermediate surgical risk is warranted. Registration URL: crd.york.ac.uk/prospero/. Unique identifier: CRD42021228752.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Infarto do Miocárdio , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Reoperação , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Infarto do Miocárdio/etiologia , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Fatores de Risco , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
4.
Adipocyte ; 11(1): 630-642, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36384443

RESUMO

Components of the growth hormone (GH) axis, such as insulin-like growth factor-1 (IGF-1), IGF-1 binding protein-3 (IGFBP-3), GH receptor (GHR) and GH-binding protein (GHBP), regulate growth and metabolic pathways. Here, we asked if serum levels of these factors are altered with overweight/obesity and if this is related to adipose tissue (AT) expression and/or increased fat mass. Furthermore, we hypothesized that expression of GHR, IGF-1 and IGFBP-3 is associated with AT function. Serum GHBP levels were increased in children with overweight/obesity throughout childhood, while for IGF-1 levels and the IGF-1/IGFBP-3 molar ratio obesity-related elevations were detectable until early puberty. Circulating levels did not correlate with AT expression of these factors, which was decreased with overweight/obesity. Independent from obesity, expression of GHR, IGF-1 and IGFBP-3 was related to AT dysfunction,and increased insulin levels. Serum GHBP was associated with liver fat percentage and transaminase levels. We conclude that obesity-related elevations in serum GHBP and IGF-1 are unlikely to be caused by increased AT mass and elevations in GHBP are more closely related to liver status in children. The diminished AT expression of these factors with childhood obesity may contribute to early AT dysfunction and a deterioration of the metabolic state.


Assuntos
Proteína 3 de Ligação a Fator de Crescimento Semelhante à Insulina , Obesidade Infantil , Criança , Humanos , Fator de Crescimento Insulin-Like I/metabolismo , Sobrepeso , Tecido Adiposo/metabolismo
5.
JACC Cardiovasc Interv ; 15(11): 1126-1136, 2022 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-35680192

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is generally performed without control over the alignment of the bioprosthesis to the native aortic valve (AV) commissures. Data on the impact of commissural misalignment (CMA) on the clinical and hemodynamic outcome after TAVR are scarce. OBJECTIVES: The aim of this study was to investigate the impact of commissural misalignment (CMA) on the clinical and hemodynamic outcome in patients with severe tricuspid aortic stenosis undergoing TAVR using the balloon-expandable (BE) SAPIEN 3 valve (Edwards LifeSciences). METHODS: Clinical data of consecutive patients who underwent BE TAVR at Cedars-Sinai Medical Center (Los Angeles, California, USA) enrolled in the RESOLVE (Assessment of TRanscathetER and Surgical Aortic BiOprosthetic Valve Thrombosis and Its TrEatment With Anticoagulation) registry were retrospectively analyzed to evaluate CMA, which was defined as a neocommissure position >30° compared with native commissures on computed tomography. RESULTS: A total of 324 patients (36.6% female, median Society of Thoracic Surgeons score of 3.9%) were included in the analysis. CMA was present in 171 individuals (52.8%). At 30 days, rates of aortic regurgitation greater than mild (5.6%) and a residual AV gradient ≥20 mm Hg (7.4%) were not different between CMA and non-CMA patients. Commissural orientation was independently associated with a relative AV mean gradient increase >50% from discharge to 30 days (per increase of 10° misalignment; OR: 1.3; 95% CI: 1.0-1.4; P = 0.01). The long-term composite outcome of death or stroke was not different between groups (log-rank P = 0.29). CONCLUSIONS: In patients with severe tricuspid aortic stenosis who undergo SAPIEN 3 TAVR, the neocommissures align randomly. Our data demonstrate that commissural alignment may impact device performance and clinical outcomes in patients undergoing BE TAVR. (Assessment of TRanscathetEr and Surgical Aortic BiOprosthetic VaLVve Dysfunction with Multimodality Imaging and Its TrEatment with Anticoagulation [RESOLVE]; NCT02318342).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Anticoagulantes , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Hemodinâmica , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Trombose , Resultado do Tratamento
8.
JACC Cardiovasc Interv ; 13(22): 2617-2627, 2020 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-33213747

RESUMO

OBJECTIVES: The aim of this study was to evaluate the risk of coronary obstruction due to sinus sequestration in redo transcatheter aortic valve replacement (TAVR) using post-TAVR computed tomography (CT). BACKGROUND: Little information is available regarding the risk of coronary obstruction due to sinus sequestration in redo TAVR inside a previously implanted TAV. METHODS: Post-TAVR CT of 66 patients who received an Evolut R or Evolut PRO and 345 patients who received a SAPIEN 3 were analyzed. Redo TAVR was considered at risk of coronary obstruction due to sinus sequestration if: 1) the prior TAV commissure level was above sinotubular junction (STJ); and 2) the distance between TAV and STJ was <2.0 mm in each coronary sinus. RESULTS: In total, 45.5% in the Evolut R/Evolut PRO group and 2.0% in the SAPIEN 3 group had CT-identified risk of sinus sequestration at 1 or both coronary arteries (p < 0.001). CT-identified risk of sinus sequestration was observed in 39.4% for the left coronary artery and 24.2% for the right coronary artery in the Evolut R/Evolut PRO group, while those percentages were 2.0% for the left coronary artery and 0.6% for the right coronary artery in the SAPIEN 3 group. In a coronary-level analysis, overlaps between the first TAV commissural posts and coronary ostium were observed in 45.2% in the Evolut R/Evolut PRO group and 11.1% in in the SAPIEN 3 group among coronary arteries at CT-identified risk of sinus sequestration. CONCLUSIONS: The risk of sinus sequestration in redo TAVR should be carefully screened by CT, especially in patients with low STJ height. TAV with low commissure height that was designed to achieve commissure-to-commissure alignment with the native aortic valves may be preferable to avoid the risk of coronary obstruction due to sinus sequestration and allow for a preventive leaflet laceration procedure in future redo TAVR. (Assessment of TRanscathetEr and Surgical Aortic BiOprosthetic Valve Thrombosis and Its TrEatment With Anticoagulation [RESOLVE]; NCT02318342).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
10.
Am J Cardiol ; 133: 105-115, 2020 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-32811649

RESUMO

Scarce data exist on clinical features and prognosis of patients with severe aortic stenosis (AS), concomitant with left ventricular obstruction (LVO). We aimed to evaluate the prevalence, characteristics, and outcomes in patients with severe AS and LVO undergoing transcatheter aortic valve implantation (TAVI). Consecutive patients with severe AS undergoing TAVI between January 2013 to December 2017 at our institution were included. Significant LVO was defined as resting peak left ventricular (LV) systolic gradient ≥30 mm Hg on pre-TAVI echocardiography. We analyzed the primary composite outcome of all-cause mortality and rehospitalization for heart failure (HHF) at 1-year in patients with LVO and those without LVO in the overall and propensity-matched populations. Among 1,729 patients who underwent TAVI, significant LVO was observed in 31 (1.8%) patients. This group was more likely to be female, had smaller aortic annulus and LV cavity, and received a smaller size of the transcatheter heart valve. The most common phenotype of LV hypertrophy causing LVO was concentric LV hypertrophy (58%), and mid-LV obstruction was more common than LV outflow tract obstruction (77% vs 23%, respectively). After adjustment for baseline differences, the primary outcome was not significantly different between patients with LVO and those without LVO (15% vs 16%, respectively; hazard ratio: 0.83; 95% confidence interval: 0.19 to 3.72; p = 0.809). In conclusion, in patients undergoing TAVI, concomitant LVO was relatively uncommon and occurred more often at mid-LV. The presence of pre-TAVI LVO was not associated with worse outcomes defined as increase all-cause mortality or HHF at 1-year.


Assuntos
Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Insuficiência Cardíaca/epidemiologia , Substituição da Valva Aórtica Transcateter , Obstrução do Fluxo Ventricular Externo/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Feminino , Insuficiência Cardíaca/diagnóstico , Hospitalização , Humanos , Masculino , Pontuação de Propensão , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/complicações , Obstrução do Fluxo Ventricular Externo/diagnóstico
11.
J Am Heart Assoc ; 9(14): e013973, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32646262

RESUMO

Background As transcatheter aortic valve replacement (TAVR) is expected to progress into younger patient populations, valve-in-TAVR (ViTAVR) may become a frequent consideration. Data on ViTAVR, however, are limited. This study investigated the outcome of ViTAVR in comparison to valve in surgical aortic valve replacement (ViSAVR), because ViSAVR is an established procedure for higher-risk patients requiring repeated aortic valve intervention. Methods and Results Clinical and procedural data of patients who underwent ViTAVR at 3 sites in the United States and Germany were retrospectively compared with data of patients who underwent ViSAVR at Cedars-Sinai Medical Center, according to Valve Academic Research Consortium-2 criteria. A total of 99 consecutive patients, 52.5% women, with a median Society of Thoracic Surgeons score of 7.2 were identified. Seventy-four patients (74.7%) underwent ViSAVR, and 25 patients (25.3%) underwent ViTAVR. Balloon-expandable devices were used in 72.7%. ViSAVR patients presented with smaller index devices (21.0 versus 26.0 mm median true internal diameter; P<0.001). Significantly better postprocedural hemodynamics (median prosthesis mean gradient, 12.5 [interquartile range, 8.8-16.2] versus 16.0 [interquartile range, 13.0-20.5] mm Hg; P=0.045) were observed for ViTAVR compared with the ViSAVR. Device success, however, was not different (79.2% and 66.2% for ViTAVR and ViSAVR, respectively; P=0.35), as were rates of permanent pacemaker implantation (16.7% versus 5.4%; P=0.1). One-year-mortality was 9.4% and 13.4% for ViTAVR and ViSAVR, respectively (log-rank P=0.38). Conclusions Compared with ViSAVR, ViTAVR provides acceptable outcomes, with slightly better hemodynamics, similar device success rates, and similar 1-year mortality.


Assuntos
Valva Aórtica , Bioprótese/estatística & dados numéricos , Próteses Valvulares Cardíacas/estatística & dados numéricos , Falha de Prótese , Reoperação/mortalidade , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Alemanha/epidemiologia , Hemodinâmica , Humanos , Masculino , Estudos Retrospectivos , Estados Unidos/epidemiologia
12.
JAMA Cardiol ; 5(3): 346-355, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31995124

RESUMO

Importance: Most patients with severe degenerative mitral regurgitation (DMR) are likely to require surgery, but years can pass until there is a clear indication for it. The timing of mitral valve surgery for asymptomatic patients with severe DMR is controversial, and current guidelines are limited because they are based on nonrandomized studies and expert opinion. Observations: In this narrative review, a decrease in left ventricular ejection fraction and an increase in left ventricular end-systolic diameter are adverse signs in the context of mitral regurgitation. Consequently, serial echocardiography is essential. However, measurements may be imprecise, and the evidence regarding the association with outcome in asymptomatic patients is inconsistent. Mitral valve repair is the preferred surgical approach; however, repair rate, durability, and outcomes vary between centers, rendering decision-making in an asymptomatic patient with DMR even more challenging. The use of natriuretic peptides, stress testing, cardiac magnetic resonance imaging, and myocardial strain imaging can aid in risk stratification and optimization of the timing of mitral valve surgery in an asymptomatic patient. Conclusions and Relevance: Management of asymptomatic patients with DMR requires a comprehensive approach that goes beyond the guidelines. Close follow-up and the use of multiple modalities are recommended. Knowledge of surgical options, experience, and outcomes is important when an intervention is considered.


Assuntos
Doenças Assintomáticas , Tomada de Decisão Clínica , Insuficiência da Valva Mitral/cirurgia , Biomarcadores/sangue , Ecocardiografia , Teste de Esforço , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética , Insuficiência da Valva Mitral/diagnóstico por imagem , Peptídeo Natriurético Encefálico/sangue , Medição de Risco , Índice de Gravidade de Doença , Volume Sistólico , Sístole , Tempo para o Tratamento
15.
J Am Coll Cardiol ; 74(9): 1190-1200, 2019 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-31466616

RESUMO

BACKGROUND: There is paucity of evidence on the impact of anticoagulation (AC) after bioprosthetic aortic valve replacement (AVR) on valve hemodynamics and clinical outcomes. OBJECTIVES: The study aimed to assess the impact of AC after bioprosthetic AVR on valve hemodynamics and clinical outcomes. METHODS: Data on antiplatelet and antithrombotic therapy were collected. Echocardiograms were performed at 30 days and 1 year post-AVR. Linear regression model and propensity-score adjusted cox proportional model were used to assess the impact of AC on valve hemodynamics and clinical outcomes, respectively. RESULTS: A total of 4,832 patients undergoing bioprosthetic AVR (transcatheter aortic valve replacement [TAVR], n = 3,889 and surgical AVR [SAVR], n = 943) in the pooled cohort of PARTNER2 (Placement of Aortic Transcatheter Valves) randomized trials and nonrandomized registries were studied. Following adjustment for valve size, annular diameter, atrial fibrillation, and ejection fraction at the time of assessment of hemodynamics, there was no significant difference in aortic valve mean gradients or aortic valve areas between patients discharged on AC vs. those not discharged on AC, for either TAVR or SAVR cohorts. A significantly greater proportion of patients not discharged on AC had an increase in mean gradient >10 mm Hg from 30 days to 1 year, compared with those discharged on AC (2.3% vs. 1.1%, p = 0.03). There was no independent association between AC after TAVR and adverse outcomes (death, p = 0.15; rehospitalization, p = 0.16), whereas AC after SAVR was associated with significantly fewer strokes (hazard ratio [HR]: 0.17; 95% confidence interval [CI]: 0.05-0.60; p = 0.006). CONCLUSIONS: In the short term, early AC after bioprosthetic AVR did not result in adverse clinical events, did not significantly affect aortic valve hemodynamics (aortic valve gradients or area), and was associated with decreased rates of stroke after SAVR (but not after TAVR). Whether early AC after bioprosthetic AVR has impact on long-term outcomes remains to be determined. (Placement of AoRTic TraNscathetER Valves [PARTNERII A]; NCT01314313).


Assuntos
Anticoagulantes/farmacologia , Valva Aórtica/efeitos dos fármacos , Valva Aórtica/fisiologia , Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Hemodinâmica/efeitos dos fármacos , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/uso terapêutico , Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Período Pós-Operatório , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter , Resultado do Tratamento
16.
JAMA Netw Open ; 2(6): e196126, 2019 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-31225892

RESUMO

Importance: Changes in estradiol during aging are associated with increased dementia risk. It remains unclear how estradiol supports cognitive health and whether risk factors, such as midlife obesity, are exacerbated by estrogen loss. Objectives: To assess whether visceral adipose tissue (VAT) moderates the association between age and brain network structure and to investigate whether estradiol moderates the association between VAT and brain network structure. Design, Setting, and Participants: Cross-sectional study of data from 974 cognitively healthy adults in Germany who participated in the Health Study of the Leipzig Research Centre for Civilization Diseases, a previously described population-based cohort study. Two moderation analyses were performed, including VAT as the moderator variable between age and brain network structure and estradiol as the moderator variable between VAT and brain network structure. The study was conducted from August 1, 2011, to November 23, 2014. Analyses were conducted from August 2017 to September 2018. Exposures: Serum estradiol levels from fasting blood and visceral adipose tissue volume from T1-weighted magnetic resonance imaging (MRI). Main Outcomes and Measures: Brain network covariance (individual loading on structural network derived from T1-weighted MRI) and memory performance (composite score from the Consortium to Establish a Registry for Alzheimer Disease [CERAD] verbal episodic memory test on learning [score range, 0-30], recall [score range, 0-10], and recognition [score range, 0-20]). Results: Final analyses included data from 473 women (mean [SD] age, 50.10 [15.63] years) and 501 men (mean [SD] age, 51.24 [15.67] years). Visceral adipose tissue was associated with an exacerbation of the negative association of aging with network covariance for women (interaction term ß = -0.02; 95% bias-corrected bootstrap CI, -0.03 to -0.01; P = .001) and men (interaction term ß = -0.02; 95% bias-corrected bootstrap CI, -0.03 to -0.01; P < .001). Estradiol level was associated with a reduction in the negative association of VAT with network covariance in women (interaction term ß = 0.63; 95% bias-corrected bootstrap CI, 0.14-1.12; P = .01), with no significant association in men. In the female midlife subgroup (age range, 35-55 years, when menopause transition occurs), low estradiol levels were associated with lower memory network covariance (Cohen d = 0.61; t80 = 2.76; P = .007) and worse memory performance (Cohen d = 0.63; t76 = 2.76; P = .007). Conclusions and Relevance: This study reports a novel association between VAT, estradiol, and structural brain networks as a potential mechanism underlying cognitive decline in women. These findings appear to highlight the need for sex-specific strategies, including VAT and hormonal screening during midlife, to support healthy cognitive aging.


Assuntos
Encéfalo/fisiologia , Estradiol/fisiologia , Gordura Intra-Abdominal/fisiologia , Memória Episódica , Rede Nervosa/fisiologia , Encéfalo/anatomia & histologia , Estudos Transversais , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Reconhecimento Psicológico/fisiologia , Aprendizagem Verbal/fisiologia
17.
Thorac Cardiovasc Surg ; 67(7): 516-523, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30114713

RESUMO

BACKGROUND: The aim of this study was to quantify acute mitral valve (MV) geometry dynamic changes throughout the cardiac cycle using three-dimensional transesophageal echocardiography (3D TEE) in patients undergoing surgical MV repair (MVR) with ring annuloplasty and optional neochord implantation. METHODS: Twenty-nine patients (63 ± 10 years) with severe primary mitral regurgitation underwent surgical MVR using ring annuloplasty with or without neochord implantation. We recorded 3D TEE data throughout the cardiac cycle before and after MVR. Dynamic changes (4D) in the MV annulus geometry and anatomical MV orifice area (AMVOA) were measured using a novel semiautomated software (Auto Valve, Siemens Healthcare). RESULTS: MVR significantly reduces the anteroposterior diameter by up to 38% at end-systole (36.8-22.7 mm; p < 0.001) and the lateromedial diameter by up to 31% (42.7-30.3 mm; p < 0.001). Moreover, the annular circumference was reduced by up to 31% at end-systole (129.6-87.6 mm, p < 0.001), and the annular area was significantly decreased by up to 52% (12.8-5.7 cm2; p < 0.001). Finally, the AMVOA experienced the largest change, decreasing from 1.1 to 0.2 cm2 during systole (at midsystole; p < 0.001) and from 4.1 to 3.2 cm2 (p < 0.001) during diastole. CONCLUSIONS: MVR reduces the annular dimension and the AMVOA, contributing to mitral competency, but the use of annuloplasty rings reduces annular contractility after the procedure. Surgeons can use 4D imaging technology to assess MV function dynamically, detecting the acute morphological changes of the mitral annulus and leaflets before and after the procedure.


Assuntos
Implante de Prótese de Valva Cardíaca , Hemodinâmica , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/instrumentação , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Resultado do Tratamento
18.
Interv Cardiol ; 13(2): 62-65, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29928309

RESUMO

Bicuspid aortic valve is the most common congenital cardiac malformation. Aortic valve replacement is often required in older patients but the surgical risk is often extremely high. As Transcatheter aortic valve implantation (TAVI) is an established therapy for intermediate and high surgical risk patients with symptomatic severe aortic valve stenosis (AS). Advances in technology and knowledge have led to TAVI being used for other pathologies and populations such as bicuspid AS. Recently, the diagnosis and classification of bicuspid aortic valve based on multidetector computed tomography (MDCT) assessment has been proposed, which may have an impact of outcomes after TAVI. This review article describes the advancements in diagnosis and outcomes of bicuspid AS.

20.
BMC Public Health ; 15: 691, 2015 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-26197779

RESUMO

BACKGROUND: The LIFE-Adult-Study is a population-based cohort study, which has recently completed the baseline examination of 10,000 randomly selected participants from Leipzig, a major city with 550,000 inhabitants in the east of Germany. It is the first study of this kind and size in an urban population in the eastern part of Germany. The study is conducted by the Leipzig Research Centre for Civilization Diseases (LIFE). Our objective is to investigate prevalences, early onset markers, genetic predispositions, and the role of lifestyle factors of major civilization diseases, with primary focus on metabolic and vascular diseases, heart function, cognitive impairment, brain function, depression, sleep disorders and vigilance dysregulation, retinal and optic nerve degeneration, and allergies. METHODS/DESIGN: The study covers a main age range from 40-79 years with particular deep phenotyping in elderly participants above the age of 60. The baseline examination was conducted from August 2011 to November 2014. All participants underwent an extensive core assessment programme (5-6 h) including structured interviews, questionnaires, physical examinations, and biospecimen collection. Participants over 60 underwent two additional assessment programmes (3-4 h each) on two separate visits including deeper cognitive testing, brain magnetic resonance imaging, diagnostic interviews for depression, and electroencephalography. DISCUSSION: The participation rate was 33 %. The assessment programme was accepted well and completely passed by almost all participants. Biomarker analyses have already been performed in all participants. Genotype, transcriptome and metabolome analyses have been conducted in subgroups. The first follow-up examination will commence in 2016.


Assuntos
Indicadores Básicos de Saúde , Nível de Saúde , Vigilância da População/métodos , População Urbana/estatística & dados numéricos , Adulto , Idoso , Estudos de Coortes , Feminino , Alemanha/epidemiologia , Inquéritos Epidemiológicos , Humanos , Masculino , Pessoa de Meia-Idade , Exame Físico , Projetos de Pesquisa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...